Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
User problem
Already-deployed Windows 10/11 CloudFile Agent opens PRT files using directly spawned
ugraf.exe -retrieve:<path>, causing a new NX window on each open. The direct-retrieveroute was validated on real customer NX 7.5 machines and must be preserved as the no-running-session fallback.Change
ugraf.exeusing native ToolHelp APIs. Inspect the actual executable path viaQueryFullProcessImageNameWwithout CMD, PowerShell, PATH or administrator privilege.ugraf.exe -retrieve:<file>launch, retaining NX7.x Unicode-path checks and detected version/working-directory rules.ugs_router.exeis available, pass-ug -use_file_dir <file>as separate native argv. This is the known Siemens association command for activating existing NX sessions, but its success must still be validated in real NX. User-defined open rules retain precedence.ugraf.exeor guess at a Teamcenter session.routed_nxin the existingopened.json(older records stay readable). Deleting a previously routed NX working copy requires explicit user confirmation even if the PID subsequently disappears. Existing file-lock check remains first, and no other files in the folder are removed.Test evidence
cargo fmt --all --check,cargo clippy --workspace --all-targets --locked -- -D warnings, andcargo test --workspace --locked --no-fail-fastall PASS (one pre-existing ignored OS-keyring test).ticks.is_multiple_of(150)Rust lint and the stale installer-guard Node test update already in fix(agent2): periodic update checks, portable Win10/11 compatibility and clearer V2 errors #30 so the Windows CI baseline can actually run, without changing installers. Reconcile these identical baseline fixes after fix(agent2): periodic update checks, portable Win10/11 compatibility and clearer V2 errors #30 is merged.Gate before merge or publishing
Draft: not real Windows/NX verification. Must verify Win10 and Win11 ordinary-user workstations with NX7.5, NX12, NX2306+; absent/one/multiple sessions; managed Teamcenter; file route from Chrome, same-file repeat, local-view/edit, commit/upload and deletion protection. Correct result means the file actually appears in the existing NX session, not merely that
ugs_router.exeexited 0. Do not merge or deploy on CI alone.CI / Windows installer compatibility follow-up
[WARN]/[ERROR]tags before existing Chinese messages, to make Windows CI fail-closed checks and support logs stable across Windows code pages..gitattributesnow marks the-textCMD files aswhitespace=cr-at-eolsogit diff --checkcorrectly accepts mandatory CRLF while still prohibiting Git encoding/newline conversion. Added small deterministic installer tests asserting the exact safety tags. No scripts are executed on live customer machines.